Summary Statistics

Making fair comparisons between higher education institutions is always challenging due to the rich diversity of higher education. The unverified nature of the information in this database and unavailability of unbiased normalization metrics means such comparisons are even more difficult. Users should therefore approach direct institution to institution comparisons with caution and recognize that all comparisons between institutions are inherently biased.
Total Per Full-Time Enrollment Per 1000 Square Feet % Offset
Gross emissions (Scopes 1 + 2) 15,073 metric tons of CO2e 3.0 metric tons of CO2e 12.0 metric tons of CO2e 2%
Gross emissions (Scopes 1 + 2 + 3) 23,743 metric tons of CO2e 4.7 metric tons of CO2e 18.9 metric tons of CO2e 1%
Net emissions 23,448 metric tons of CO2e 4.6 metric tons of CO2e 18.6 metric tons of CO2e N/A

Emissions Inventory Methodology and Boundaries

Start date of the 12-month period covered in this report July 1, 2009
Consolidation methodology used to determine organizational boundaries Equity share approach
If any institution-owned, leased, or operated buildings or other holdings that should fall within the organizational boundaries are omitted, briefly explain why.

Only the main campus facilities are included in the inventory

Emissions calculation tool used Clean Air-Cool Planet
Please describe why this tool was selected.

No information provided

Please describe the source(s) of the emissions coefficients used.

No information provided

Which version of IPCC's list of global warming potentials did you use? No information provided
Who primarily conducted this emissions inventory? C4 Committee
Please describe the process of conducting the inventory.

Assigned tasks to committee members according to their expertise.

Please describe any emissions sources that were classified as de minimis and explain how a determination of the significance of these emissions was made.

No information provided

Please describe any data limitations related to this submission and any major assumptions made in response to these limitations.

Estimations were used for air travel mileage and commuter data. Refrigerant usage has been estimated as 10% of the actual tank capacity since the actual usage data is not available. Fertilizer data is estimated from prior year since the data is not available.

Emissions Data

Emissions from the following sources (in metric tons of CO2e)

Scope 1 Emissions
Stationary Combustion 1,656.0 metric tons of CO2e
Mobile Combustion 111.0 metric tons of CO2e
Process Emissions 4.0 metric tons of CO2e
Fugitive Emissions 1,023.0 metric tons of CO2e
Total Scope 1 emissions 2,794.0 metric tons of CO2e
Scope 2 Emissions
Purchased Electricity 12,279.0 metric tons of CO2e
Purchased Heating 0.0 metric tons of CO2e
Purchased Cooling 0.0 metric tons of CO2e
Purchased Steam 0.0 metric tons of CO2e
Total Scope 2 emissions 12,279.0 metric tons of CO2e
Scope 3 Emissions
Commuting 6,959.0 metric tons of CO2e
Air Travel 488.0 metric tons of CO2e
Solid Waste 1,223.0 metric tons of CO2e
Total Scope 3 emissions 8,670.0 metric tons of CO2e
Biogenic Emissions
Biogenic Emissions from Stationary Combustion No information provided
Biogenic Emissions from Mobile Combustion No information provided

Mitigation Data

Carbon Offsets
Carbon offsets purchased No information provided
Offset verification program(s) No information provided
Description of offsets purchased (including vendor, project source, etc.)

No information provided

Renewable Energy Certificates (RECs)
Total RECs purchased 500136 kWh
Percent of total electricity consumption mitigated through the purchase of RECs None %
Emissions reductions due to the purchase of RECs 295.0 metric tons of CO2e
REC verification program(s) No information provided
Description of RECs purchased (including vendor, project source, etc.)

No information provided

Sequestration and Carbon Storage
Sequestration due to land owned by the institution No information provided
Description of how sequestration was calculated

No information provided

Carbon storage due to composting No information provided

Normalization and Contextual Data

Building Space
Gross square feet of building space 1,257,430.0 sq ft
Net assignable square feet of laboratory space No information provided
Net assignable square feet of health care space No information provided
Net assignable square feet of residential space No information provided
Population
Total Student Enrollment (FTE) 5045.0
Residential Students No information provided
Full-time Commuter Students No information provided
Part-time Commuter Students No information provided
Non-Credit Students No information provided
Full-time Faculty No information provided
Part-time Faculty No information provided
Full-time Staff No information provided
Part-time Staff No information provided
Other Contextual Data
Endowment Size No information provided
Heating Degree Days No information provided
Cooling Degree Days No information provided
Please describe any circumstances specific to your institution that provide context for understanding your greenhouse gas emissions this year.

No information provided

Supporting Documentation

Completed inventory narrative No information provided
Completed inventory calculator Download

Auditing and Verification

These emissions data have been audited, verified, or peer-reviewed.
Please briefly describe this verification, if any.

By C4 Committee Members