Summary Statistics

Making fair comparisons between higher education institutions is always challenging due to the rich diversity of higher education. The unverified nature of the information in this database and unavailability of unbiased normalization metrics means such comparisons are even more difficult. Users should therefore approach direct institution to institution comparisons with caution and recognize that all comparisons between institutions are inherently biased.
Total Per Full-Time Enrollment Per 1000 Square Feet % Offset
Gross emissions (Scopes 1 + 2) 52,653 metric tons of CO2e 3.5 metric tons of CO2e 12.2 metric tons of CO2e 1%
Gross emissions (Scopes 1 + 2 + 3) 109,640 metric tons of CO2e 7.3 metric tons of CO2e 25.3 metric tons of CO2e 1%
Net emissions 109,020 metric tons of CO2e 7.2 metric tons of CO2e 25.2 metric tons of CO2e N/A

Emissions Inventory Methodology and Boundaries

Start date of the 12-month period covered in this report July 1, 2006
Consolidation methodology used to determine organizational boundaries Operational control approach
If any institution-owned, leased, or operated buildings or other holdings that should fall within the organizational boundaries are omitted, briefly explain why.

All buildings under Towson University's ownership and operation were accounted for.

Emissions calculation tool used Clean Air-Cool Planet
Please describe why this tool was selected.

The Clean Air-Cool Planet (CA-CP) calculator was selected for a variety of reasons.It is endorsed by ACUPCC and due to its widespread use provides a standard measuring tool allowing universities to benchmark against one another. It is consistent with the Greenhouse Gas Protocol. New versions and updates are constantly available for the CA-CP calculator and CA-CP representatives are readily available for any questions or comments.

Please describe the source(s) of the emissions coefficients used.

The CA-CP calculator bases many of its emissions coefficients from US governmental and intergovernmental (IPCC) data.

Which version of IPCC's list of global warming potentials did you use? Third Assessment Report
Who primarily conducted this emissions inventory? External consultant
Please describe the process of conducting the inventory.

The emissions inventory data was managed and coordinated by an outside consultant with the assistance of faculty and staff on campus collecting data. Departments advantageous to the data collection process were determined based on the emissions sections of the CA-CP calculator. A timeframe of two months was allocated to inform the departments of what information was needed and for the departments to retrieve the data. The outside consultant performed the emissions calculations using the CA-CP tool and after quality control and benchmarking comparisons were made, the final GHG inventory report was issued. For a more in-depth description please visit the webpage below.

http://www.towson.edu/main/abouttu/newsroom/greenhouseaudit101408.asp

Please describe any emissions sources that were classified as de minimis and explain how a determination of the significance of these emissions was made.

No information provided

Please describe any data limitations related to this submission and any major assumptions made in response to these limitations.

All buildings under Towson University's ownership and operation were accounted for.

Emissions Data

Emissions from the following sources (in metric tons of CO2e)

Scope 1 Emissions
Stationary Combustion 13,105.1 metric tons of CO2e
Mobile Combustion 753.1 metric tons of CO2e
Process Emissions 22.1 metric tons of CO2e
Fugitive Emissions 366.0 metric tons of CO2e
Total Scope 1 emissions 14,246.3 metric tons of CO2e
Scope 2 Emissions
Purchased Electricity 38,406.9 metric tons of CO2e
Purchased Heating 0.0 metric tons of CO2e
Purchased Cooling 0.0 metric tons of CO2e
Purchased Steam 0.0 metric tons of CO2e
Total Scope 2 emissions 38,406.9 metric tons of CO2e
Scope 3 Emissions
Commuting 45,852.8 metric tons of CO2e
Air Travel 3,732.3 metric tons of CO2e
Solid Waste 3,538.6 metric tons of CO2e
Waste Water 64.1 metric tons of CO2e
T&D Losses 3,798.5 metric tons of CO2e
Total Scope 3 emissions 56,986.3 metric tons of CO2e
Biogenic Emissions
Biogenic Emissions from Stationary Combustion No information provided
Biogenic Emissions from Mobile Combustion No information provided

Mitigation Data

Carbon Offsets
Carbon offsets purchased No information provided
Offset verification program(s) No information provided
Description of offsets purchased (including vendor, project source, etc.)

No information provided

Renewable Energy Certificates (RECs)
Total RECs purchased None kWh
Percent of total electricity consumption mitigated through the purchase of RECs None %
Emissions reductions due to the purchase of RECs No information provided
REC verification program(s) No information provided
Description of RECs purchased (including vendor, project source, etc.)

No information provided

Sequestration and Carbon Storage
Sequestration due to land owned by the institution 620.0 metric tons of CO2e
Description of how sequestration was calculated

The average carbon density of US forestland of 40.9 metric tons of eCO2 per acre was used to estimate the amount of eCO2 sequestered by the 15.163 acres of forest in easement (www.epa.gov/cleanenergy/energy-resources/refs.html - acres of forest preserved from deforestation).

Carbon storage due to composting No information provided

Normalization and Contextual Data

Building Space
Gross square feet of building space 4,332,123.0 sq ft
Net assignable square feet of laboratory space 217,499.0 sq ft
Net assignable square feet of health care space 182,273.0 sq ft
Net assignable square feet of residential space 1,355,401.0 sq ft
Population
Total Student Enrollment (FTE) 15086.0
Residential Students No information provided
Full-time Commuter Students 17422
Part-time Commuter Students No information provided
Non-Credit Students No information provided
Full-time Faculty 1375
Part-time Faculty No information provided
Full-time Staff 1659
Part-time Staff No information provided
Other Contextual Data
Endowment Size No information provided
Heating Degree Days No information provided
Cooling Degree Days No information provided
Please describe any circumstances specific to your institution that provide context for understanding your greenhouse gas emissions this year.

Included in the campus fleet data is the use of college, personal, and rented vehicles for business, athletics, and recruitment travel associated with Towson University.

Supporting Documentation

Completed inventory narrative GHG Inventory Report
Download
Completed inventory calculator Download

Auditing and Verification

These emissions data have been audited, verified, or peer-reviewed.
Please briefly describe this verification, if any.

The outside consultant performed the emissions calculations using the CA-CP tool and performed a quality control check along with benchmarking comparisons of net emissions of other like institutions.